Portable Dewpoint Meter model SADP
offers an easy to use hygrometer for fast and reliable trace moisture measurement. Designed to operate at atmospheric pressure, the Model SADP features a large, easy to read analogue indicator scaled in °C dewpoint, °F dewpoint and corresponding parts per million (ppm(v)) range. The TR versions of the Shaw SADP offer the 0-10 ppm(v) range expanded over the full scale, which is selected by means of the rotary switch on the front panel. This allows for accurate measurement below 10 ppm(v).
Features:
- Intrinsically safe to ATEX and IECEx standards
- Various ranges: overall range -100 °C to +20 °C (-148 °F to +68 °F) dewpoint
- Extended range for 0 - 10 ppm (TR version only)
- Analogue display, indication in °C, °F and ppm(v)
- “AutoCal” calibration featureUSP and compliant
- Desiccant dry-down chamber for instantaneous readings
- Standard“C” type battery operation
- Self-contained, robust and reliable
- Fully portable
- Simple to operate
- Over 150 hours continuous operation
- Supplied with Calibration Certificate traceable to National & International Humidity Standards
Specifications:
- Sensing Element: Shaw Ultra High Capacitance Aluminium Oxide Sensor
- Ranges
- P (Purple): -100 to 0 °C dewpoint, 0 - 6,000 ppm(v)
- S (Silver) : -100 to -20 °C dewpoint, 0 - 1,000 ppm(v)
- G (Grey) : -80 to 0 °C dewpoint, 0 - 6,000 ppm(v)
- R (Red) : -80 to -20 °C dewpoint, 0 - 1,000 ppm(v)
- B (Blue) : -80 to +20 °C dewpoint, 0 - 23,000 ppm(v)
- Intrinsic Safety Certification :
- ATEX: II 1 G Ex ia IIC T6 Ga
- IECEx: Ex ia IIC T6 Ga
- AutoCal: Field calibration/span check facility. Activated and operated via potentiometer on the front of the instrument
- Factory Calibration: Supplied with Certificate of Calibration traceable to National Physical Laboratory (NPL)
- Accuracy:
- ± 3 °C/ ± 4 °C (± 5.4 °F/ ± 7.2 °F) dewpoint
- NPL traceable -90 °C to +20 °C (-130 °F to +68 °F)
- Response Times:
- Wet to dry: -20 °C to -60 °C - less than 120 secs
- Dry to wet: -100 °C to -20 °C - less than 20 secs
- Sample Flow Rate:
- Flow independent but ideally 2 to 5 litres per minute
- Max: 20 litres/min
- Warm Up Time: 5 seconds
- Display: Analogue: 120 mm Taut Band indicating meter showing dewpoint and ppm with amplified range of 0 - 10 ppm on TR versions.
- Power Supply: 9 V DC – six “C” type batteries (included)
- Battery Life: In excess of 150 hours continuous operation
- Resolution: 0.1 °C, 0.2 °F dewpoint or 0.1 ppm(v)
- Repeatability: Better than ±0.5 °C (±0.9 °F) dewpoint
Accessories:
- SU3 Sample Plate
- SU2 Sample Plate
- Pressure Regulator
- Flow Meter
- Service Kit