HORIBA LAQUA EC1500 Benchtop Meters

    Benchtop Conductivity Meter

    Simple and Affordable
    Ideal for routine applications and student training.
    Good value for money: no fancy bells and whistles which sounds good but are rarely used.

 

Features:

・Provides accurate conductivity readings with auto temperature compensation
・Accepts up to 5 conductivity calibration points
・Auto calibrates 84μS/cm, 1413μS/cm, 12.88mS/cm, & 111.8mS/cm standards
・ Displays average calibration factor
・Allows 1-point salinity calibration and
・temperature calibration
・With pre-programmed TDS and salinity curves for various applications

 

Specifications:

 

LAQUA-EC1500
Conductivity/Resistivity/TDS/Salinity/Temp (°C/°F) Bench Meter
Conductivity Range 0.00 μS - 200.0 mS
     Resolution 0.01 / 0.1 / 1 µS ; 0.01 / 0.1 mS
     Accuracy ±0.6% full scale, ±1.5% full scale > 18.0 mS/cm
     Reference Temperature 15.0 to 30.0 °C (adjustable)
     Temperature Coefficient 0.00 to 10.00 % per °C (adjustable)
     Cell Constants 0.070 to 13.00 (adjustable)
     Calibration Points Up to 4 (Auto) / Up to 5 (Manual)
     Units S/cm, S/m (Auto ranging)
Resistivity Range 0.000 Ω•cm to 20.0 MΩ•cm
     Resolution 0.5% full scale
     Accuracy ±0.6% full scale,  ±1.5% full scale > 1.80 MΩ•cm
Total Dissolved Solids (TDS) Range 0 ppm - 100 ppt
     Resolution 0.01 / 0.1 / 1 ppm ; 0.01 / 0.1 ppt 
    Accuracy ±0.1% full scale
    TDS Curves EN27888, 442, NaCl, Linear (0.40 to 1.00)
Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 %
     Resolution 0.1 ppt / 0.01%
    Accuracy ±0.2% full scale
    Salinity Curves NaCl / Seawater
    Calibration Option Yes 
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
     Resolution 0.1 °C / °F
    Accuracy ± 0.5 °C / ± 0.9 °F
     Calibration Option Yes ( ± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory 1000 data sets
Auto Data Log Yes
Measurement Modes  Auto Stable / Auto Hold  / Real Time
Auto Shut-Off  Yes (programmable: 1 to 30 mins.)
Electrode Status On screen display
PC / Printer Communication Phono jack (USB / RS232)
Meter Inputs BNC, phono (ATC), DC sockets
Display Static segment LCD with 160 segments
Power Requirement AC adaptor 100 - 240V, 50 - 60Hz
Dimensions 155 (L) x 150 (W) x 67 (H) mm 
Weight Approx. 730g
Electrode Stand Integrated

Meter Kit Available: 

 
EC1500
3200899658
● Meter with integrated electrode stand
● Universal power adaptor with 6 plugs
● Manual
EC1500-S
3200899661
● EC1500
● 9382-10D plastic body conductivity cell k=1.0 with built-in temperature sensor
● 503-S Conductivity standard solutions kit